Orion-system MODGAS-XWR Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Matériel Orion-system MODGAS-XWR. Orion System MODGAS-XWR User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 28
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
OE377-26-00060
(AAON Part No. V20780)
MODGAS-XWR Controller
Technical Guide
YS102530 REV 1
GAS VALVE 2
GAS VALVE 1
PO-IGN2
PO-IGN1
COMMON
RLY4
RLY3
RLY2
RLY1
WATTMASTER
CONTROLS
MADE IN USA
AUX BIN
HEAT EN
RESET IN
OPTIONS
SAT
GND
AUX AIN
GND
STATUS
ALARM
COMM
POWER
ANODE
ANODE
ANODE
M
ENTER
UP
DOWN
ALARM
MENU
OE377-26-00060
MODGAS-XWR
AAON No.: V20780
WattMaster No:
#SW000055
Rev.: 1A
E-BUS
CONNECT
I2C
CONNECT
+24 VAC
GND
CONTACT RATING
IS 1 AMP MAX
@ 24 VAC
HEAT 1
LOW SPEED
FAN
PROOF OF IGNITION 1
PROOF OF IGNITION 2
GAS VALVE 2
GAS VALVE 1
GAS VALVE
TERMINALS
HEAT 2
COMMON
RELAY OUTPUT
TERMINALS
INPUT TERMINALS (TYPE)
HEAT ENABLE (BI)
AUX. (BI)
GND
RESET INPUT (AI)
SAT INPUT (AI)
GND(AI)
GND
AUX. (AI)
www.aaon.com
Factory Packaged Controls
Vue de la page 0
1 2 3 4 5 6 ... 27 28

Résumé du contenu

Page 1 - Technical Guide

OE377-26-00060(AAON Part No. V20780)MODGAS-XWR Controller Technical GuideYS102530 REV 1GAS VALVE 2GAS VALVE 1PO-IGN2PO-IGN1COMMONRLY4RLY3RLY2RLY1WATTM

Page 2 - TABLE OF CONTENTS

WIRING MODGAS-XWR Technical Guide 10Fan EnableLow Speed FanYS102530 REV 1GAS VALVE 2GAS VALVE 1PO-IGN2PO-IGN1COMMONRLY4RLY3RLY2RLY1WATTMASTERCON

Page 3 - General Information

MODGAS-XWR Technical Guide WIRING11Fan EnableLow Speed FanYS102530 REV 1GAS VALVE 2GAS VALVE

Page 4

ZoneZoneINPUTS & OUTPUTS12 MODGAS-XWR Technical Guide Inputs and OutputsTable 1: MODGAS-XWR Controller Inputs & Outputs An

Page 5 - Stand-Alone Wiring

OPERATION MODES & STAGING CONFIGURATIONS13 MODGAS-XWR Technical Guide Operation Modes & Staging Con

Page 6

LCD DISPLAY SCREENS MODGAS-XWR Technical Guide 14Navigation KeysLCD Display Screen & Navigation KeysThe MODGAS-XWR Controller allows you to mak

Page 7

MODGAS-XWR Technical Guide LCD DISPLAY SCREENS15Main Screens Map and MODGAS ScreensMain MODGAS ScreensRefer to the foll

Page 8

LCD DISPLAY SCREENS MODGAS-XWR Technical Guide 16Status ScreensStatus ScreensRefer to the following map when navigating through the Status Screens. Fr

Page 9

MODGAS-XWR Technical Guide LCD DISPLAY SCREENS17Alarm ScreensRefer to the following map when viewing Alarm Screens. The

Page 10 - WIRING

LCD DISPLAY SCREENS MODGAS-XWR Technical Guide 18Force Valve & Confi guration ScreensForce Valve ScreensRefer to the following map when navigating

Page 11 - Communicating Wiring

MODGAS-XWR Technical Guide LCD DISPLAY SCREENS19Confi guration & Diagnostic ScreensADDRESS1 TO 4TMPSCALEFAHRENHT CUR

Page 12 - Inputs and Outputs

TABLE OF CONTENTS MODGAS-XWR Technical Guide 2OVERVIEW & FEATURES ...

Page 13 - Operation Modes

TROUBLESHOOTING MODGAS-XWR Technical Guide 20LED DiagnosticsLED DiagnosticsThe MODGAS-XWR Controller is equipped with LEDs that can be used to veri

Page 14 - Navigation Keys

MODGAS-XWR Technical Guide TROUBLESHOOTING21Figure 10: MODGAS-XWR Controller LED Locations and DescriptionsYS1025

Page 15 - Protected Screens Map

TROUBLESHOOTING MODGAS-XWR Technical Guide 22Troubleshooting AlarmsMechanical Failure:• Check relay outputs on the MODGAS-XWR for 24 VAC output.•

Page 16 - Status Screens

MODGAS-XWR Technical Guide TROUBLESHOOTING23TroubleshootingOther Checks0-3.3V (SAT OPTIONS Jumper Setting 1) &

Page 17 - Alarm & Setpoint Screens

TROUBLESHOOTING MODGAS-XWR Technical Guide 24Table 6, cont.: 0-5V Temperature Sensor - Voltage & Resistance for Type III SensorsThermistor Sen

Page 18

MODGAS-XWR Technical Guide APPENDIX A25Supply Air Temperature Sensor InstallationMounting the Supply

Page 19 - Diagnostic Screens

APPENDIX A MODGAS-XWR Technical Guide 26SAT Sensor Wiring Guide & Jumper SettingsSAT Options Jumper SettingsRefer to Tables 8 & 9 to determin

Page 20 - LED Diagnostics

MODGAS-XWR Technical Guide APPENDIX B27MODGAS-XWR Replacement of MODGAS IIReplacing the MODGAS II wit

Page 21 - Troubleshooting

2425 So. Yukon Ave • Tulsa, OK 74107-2728Ph: (918) 583-2266 • Fax: (918) 583-6094AAON® Manual Part No. V22330WattMaster Manual Form No: AA-MODGASXWR-T

Page 22 - Troubleshooting Alarms

MODGAS-XWR Technical Guide OVERVIEW3General InformationYS102530 REV 1GAS VALVE 2GAS VALVE 1PO-IGN2

Page 23

WIRING MODGAS-XWR Technical Guide 4Important Wiring ConsiderationsImportant Wiring ConsiderationsPlease read carefully and apply the following i

Page 24

MODGAS-XWR Technical Guide WIRING5Fan EnableLow Speed FanSeeFor SAT OPTIONS Jumper SettingsOn

Page 25

WIRING MODGAS-XWR Technical Guide 6Single Modulating Valve & 1 Fixed Heat Stage - Stand-AloneFigure 3: Single Modulating Valve & 1 Fixe

Page 26 - APPENDIX A

MODGAS-XWR Technical Guide WIRING7Fan EnableLow Speed FanSeeFor SAT OPTIONS Jumper SettingsOn

Page 27 - MODGAS-XWR

WIRING MODGAS-XWR Technical Guide 812-Relay E-BUS Expansion Module - Stand Alone One Modulating Valve with 1 Fixed Stage or Two Modulating Valve

Page 28 - Manual Part No. V22330

MODGAS-XWR Technical Guide WIRING9Fan EnableLow Speed FanYS102530 REV 1GAS VALVE 2GAS VALVE 1

Commentaires sur ces manuels

Pas de commentaire